Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Spring Loaded RTD Sensors with M12 Connectors

PR-26SL

Spring Loaded RTD Sensors with M12 Connectors | PR-26SL

Spring Loaded RTD Sensors with M12 Connectors

209,11 PR-26SL-3-100-a-0600-M12-1

  • 4-Wire, Class-A Pt100 RTDs Can be Used with 2, 3 or 4-Wire Systems
  • Temperature Range: -50 to 500°C (-58 to 932ºF) [250°C (482ºF) Max at Connector]
  • M12 A-Coded Male Connectors for Easy Installation, 2 Wiring Arrangements Available
  • Fits All Standard 0.260" Bore Thermowells (Sold Separately)
  • Probe Length Equals Thermowell Stem Length
  • Adjustable Self-Griping Spring Allows for Use in Shorter Length Thermowells
  • M12 Extension Cables, 4 to 20 mA Transmitters and Other Accessories Available
  • Large Selection of Industrial Thermowells
Sonde, elementi e assemblati RTD ( PT100 ) - Visualizza i prodotti correlati

Descrizione

Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your Instrumentation. A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.

Our RTD sensors with M12 connections provide for easy and efficient installation or removal of these sensors for preriodic calibration, troubleshooting or replacement. Gone are the days of having to pull extension cables from cable trays, or disconnect the probe leads from screw terminals in a connection head, in order to calibrate or replace the sensor. Now you simply disconnect the sensor from the extension cable saving cost and downtime. The M12 connector also provides two other important features, the keyed connector eliminates the potential for mis-wiring during installation, and the elimination of screw terminals results in a more robust connection that will not loosen when exposed to heating and cooling cycles

The Series PR-26SL Spring Loaded RTD has been designed to provide our customers with a simple, effective way to adapt our M12 enabled RTD probes for use in thermowells. To insure the best possible performance, the PR-26SL RTD has a spring loading feature that maintains contact between the probe and thermowell under static and vibration conditions. This helps to maintain good heat transfer between the thermowell and probe, as well as dampening the effect of vibration on the sensor. With a demonstrated ability to withstand 10gs of vibration between 10 and 500HZ (for 6" long and shorter probes per MIL-STD-202G, Method 204D, Test Condition A), this probe has shown its ability to withstand real-world conditions.

To select the right length probe for your application, simply measure the depth of the bore in the thermowell (the length from the top of the thermowell to the bottom of the bore as shown as the "Thermowell Stem Length" in the sketch below).



The PR-26SL sensor assembly is designed to fit into a thermowell with a stem length equal to that specified in the model number. Simply slide the sensor assembly into the thermowell until bottomed and then compress the spring while making the 1/2NPT connection. Thread sealant tape or thread compound may be used on the 1/2NPT mounting thread to insure easy removal at a later time. The position of the self-gripping spring can also be adjusted so that the sensor can be used in a shorter thermowell, simply twist the spring while sliding it along the probe stem until the needed position is reached.

The PR-26SL can also be used as a back-up sensor for a variety of applications. The spring loading feature can be adjusted to fit a variety of thermowells. The spring loading fitting can be removed altogether and replaced with a compression type fitting if a fixed mounting is needed. The probe (less spring and hex fitting) can also be used with one of Omega's M12-Handle accessories to turn your spring loaded probe into a hand-held probe. This flexibility in mounting options, as well as the simplified and robust connection provided by the M12 connector, makes the PR-26SL the perfect solution for a wide variety of applications.

These RTD sensors can be used in any 2, 3 or 4-wire application by selecting one of the two available wiring arrangements (see the wiring diagrams below) and using only those wires needed for your connection. This allows for simplified, trouble free installation with any existing application. This also allows the PR-26SL series sensor to be used for a wide variety of replacement applications since it can be connected as-is with just about any measurement or control equipment available.

 
  • Standard Probe Diameter: 1/4"

  • Standard Probe Lengths: See Thermowell Stem Lengths in The Order Table Below.

  • Sensor: Pt100 (100 Ohms at 0°C, .00385 TCR (alpha)) Standard, Pt1000 and Other Options Available.

  • Accuracy: Class A Standard (per IEC 60751), Others Available Upon Request.

  • Temperature Range: -50 to 500°C Except for the Connector Which is 250°C Max.

  • Insulation Resistance: 100 Megohms Minimum at 100VDC at Room Ambient Temperature.

  • Vibration Resistance: 10gs from 10-500Hz per MIL-STD-202G, Method 204D, Test Condition A.


  • Ordinare(Specificare il codice prodotto)
    Codice prodotto/Desc.
    Q.tá
    Descrizione
    PR-26SL-3-100-A-0250-M12-1
    196,20
    Stock: 6 settimane
     
    Resistance at 0°C;100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 2½"
    PR-26SL-3-100-A-0600-M12-1
    209,11
    Stock: 6 settimane
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 6"
    PR-26SL-3-100-A-0900-M12-1
    214,05
    Stock: 6 settimane
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 9"
    PR-26SL-3-100-A-1200-M12-1
    214,76
    Stock: 1 settimana
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 12"
    PR-26SL-3-100-A-1500-M12-1
    219,61
    Stock: 6 settimane
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 15"
    PR-26SL-3-100-A-1800-M12-1
    Consultare l'Ufficio Commerciale  
    Stock: 
     
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 18"
    PR-26SL-3-100-A-2400-M12-1
    238.46
    Stock: 6 settimane
     
    Resistance at 0°C; 100.00 ±0.06Ω, Accuracy Class Per IEC 60751; Class A, Thermowell Stem Length; 24"
    Tutti gli importi indicati in EUR
    Nota: * Class A Accuracy = ±(0.15 + 0.002*t)°C where “t” = temperature in °C regardless of sign.
    For the alternate wiring arrangement, change “-1” to “-2” in the model number, no additional cost.
    For a probe length not listed up to 24", change the stem length in the model number to the required stem length (Example: 1250 = 12½") and use the price of the next longer sensor.
    Esempio di Ordinazione: (1) PR-26SL-3-100-A-0250-M12-1 Spring Loaded Pt100 Class A RTD with M12 Connector for Use in Thermowells with a Stem Length of 2.50 inches, €196.20  plus (1) PR-26SL-3-100-A-0600-M12-1 Spring Loaded Pt100 Class A RTD with M12 Connector for Use in Thermowells with a Stem Length of 6 inches, €209.11, €196.20 + 209.11 = €405.31

    Combinare codice prodotto

    Costruisci il Tuo Codice Prodotto Qui Sotto
    Descrizione delle opzioni:


    (1) Probe Resistance Seleziona da:
    100 per 100 ohms at 0C
    1000 per 1000 ohms at 0C

    (2) Accuracy Seleziona da:
    A per Class A per IEC60751
    B per Class B per IEC60751

    (3) Thermowell Stem Length Seleziona da:
    0250 per 2.50 inches
    0400 per 4 inches
    0600 per 6 inches
    0900 per 9 inches
    1200 per 12 inches
    1500 per 15 inches
    1800 per 18 inches
    2400 per 24 inches

    (4) Wiring Arrangement Seleziona da:
    1 per See Wiring Diagram
    2 per See Wiring Diagram
    Nota: Non tutte le combinazioni possono essere valide, controlla il foglio delle specifiche per codici prodotti corretti.
    We noticed you are from the US. Visit your local site for regional offers and live support.