Cookies del sito web Omega
Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Solid State Temperature Sensor

AD590 Series

Solid State Temperature Sensors | AD590 Series

Solid State Temperature Sensors

44,30 AD590JH

  • Temperature Sensor with a Linear Current Output
  • Broad Range –55 to 150°C
  • No Linearization Circuity Required
  • Versatile and Economical
  • Fast Response Temperature Sensor
Elementi termistori , sonde e assemblati - Visualizza i prodotti correlati

Descrizione

The AD590 is a small IC temperature sensor that converts a temperature input into a proportional current output.

The advanced technology in the AD590 is especially suited for special temperature measurement and control applications between –55 and 150°C when solid state reliability, linearity and accuracy are required. The AD590 temperature sensor can be used to determine minimum, average, and differential temperatures, in addition to being used for thermocouple cold junction compensation and temperature control applications. The size and responsiveness of the AD590 IC Sensor makes it perfect for uses where size is a consideration, such as on PC boards or heat sinks.

Just power up and measure absolute temperature (Kelvin). No linearization, amplification or cold junction compensation is required.

SPECIFICATIONS
Absolute Maximum Ratings Forward Voltage (E+ to E–):
+44 V
Reverse Voltage (E+ to E–): –20 V Breakdown Voltage
(case to E+ or E–): ±200 V
Lead Temperature: 300°C
Voltage Range: +4 to +30 Vdc Nominal Current Output at 25°C
(298.2 K): 298.2 µA Nominal Temperature Coefficient: 1 µA/K
Calibration Error: J: ±5.0°C
maximum (K: ±2.5°C)
Absolute Error: w/o external
Calibration Adjustment:
J: ±10.0°C maximum (K: ±5.5°C);
W/25°C error set to zero J: ±3.0°C
maximum (K: ±2.0°C)
Repeatability: ±0.1°C maximum
Long-Term Drift: ±0.1°C/month max.
Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
AD590JF
130,39
Stock: 1 settimana
 
Temperature Sensor Featuring a Flat Pack Case, ±1.5°C linearity
AD590KF
97,70
Stock: 7 settimane
 
Temperature Sensor Featuring a Flat Pack Case, ±0.8°C linearity
AD590JH
44,30
Stock: 7 settimane
 
Temperature Sensor with a TO-52 Case, ±1.5°C linearity
AD590KH
57,30
Stock: 1 settimana
 
Temperature Sensor with a TO-52 Case, ±0.8°C linearity
Tutti gli importi indicati in EUR
Esempio di Ordinazione: (1) AD590KF AD590 temperature sensor, €97,70
We noticed you are from the US. Visit your local site for regional offers and live support.