Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

High Temperature, Low Drift, Mineral Insulated Thermocouple Cable

XL-[*]-MO

High Temperature Mineral Insulated Cable | XL-[*]-MO

High Temperature Mineral Insulated Cable

6,90 XL-K-MO-125

  • Excellent Long Term Stability at High Temperatures
  • Continuous use up to 1150°C
  • Excellent Oxidation, Carburization and Chlorination Resistance
  • High Purity MgO (HP) Available
  • Low Drift Stable Output Performance
  • Class 1 or Class 2 IEC Tolerance Available
  • Available in Thermocouple Types K or N
  • Available from STOCK! Cut to Length or Long Continuous Lengths
Filo termocoppia , RTD , termistore e cavetto di cablaggio - Visualizza i prodotti correlati

Descrizione

Super OmegaClad XL Thermal Drift Super OMEGACLAD™ XL sheathed mineral-insulated thermocouple wire can be used at high temperatures for prolonged periods with very little drift of the base metal thermocouple. The sheath material uses Nickel-Chrome based Super OMEGACLAD™ XL sheathing, which provides excellent oxidation resistance. The sheath can withstand long-term exposure to combustion gases or air at temperatures up to1150°C. Short-term exposures to higher temperatures are also possible. Superior resistance to oxidation attack results from a tenacious and protective high temperature film that does not affect the stability of the thermocouple alloys. This film permits the sensor to be used at high temperatures for prolonged periods with improved accuracy over other available sheath materials. Super OMEGACLAD™ sheathing also provides excellent resistance to corrosion in high temperature chlorine-contaminated oxidizing environments and ammonia/nitride-rich environments at temperatures above 980°C, the temperature at which the protective film forms.

Imperial
Model No.
[*] Insert Wire
Calibration
Sheath
Material
Sheath
Dia.(in)
Wall
Thickness(in)
Resistance at
15.5°C Ohms/Dbl. foot
Wire
Dia.(in)
XL-[*]-MO-010 Type K or
Type N
Omegaclad XL 0.010 0.0015 72 0.002
XL-[*]-MO-020 0.0200.003380.004
XL-[*]-MO-0320.0320.005240.005
XL-[*]-MO-040 0.0400.007150.006
XL-[*]-MO-0620.062 0.01060.01
XL-[*]-MO-1250.1250.0181.50.021
XL-[*]-MO-1880.1880.0250.590.032
XL-[*]-MO-250 0.2500.0360.370.04
XL-[*]-MO-3130.313 0.0400.350.05
Metric
Model No.
[*] Insert Wire
Calibration
Sheath
Material
Sheath
Dia.(mm)
Wall
Thickness(mm)
Resistance at
15.5°COhms/Dbl. metre
Wire
Dia.(mm)
XL-[*]-MO-0.25MM Type K or
Type N
Omegaclad XL 0.25 0.038 236 0.045
XL-[*]-MO-0.5MM0.50.076 1250.089
XL-[*]-MO-.75MM0.750.113 790.134
XL-[*]-MO-1.0MM10.152 490.178
XL-[*]-MO-1.5MM1.50.254 200.254
XL-[*]-MO-2.0MM20.305 120.356
XL-[*]-MO-3.0MM30.457 4.90.559
XL-[*]-MO-4.5MM4.50.66 1.90.787
XL-[*]-MO-6.0MM60.94 1.21.016
XL-[*]-MO-8.0MM81.016 1.11.27


Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
XL-K-MO-3.0MM
19.75
Stock: 3 settimane
 
3.0mm dia. type K MI cable. Class 2. (price per metre)
XL-K-MO-6.0MM
69.06
Stock: 2 settimane
 
6.0mm dia. type K MI cable. Class 2. (price per metre)
XL-N-MO-6.0MM
68.39
Stock: 3 settimane
 
6.0mm dia. type N MI cable. Class 2. (price per metre)
The price shown is the cost per foot (imperial diameters) or metre (metric diameters). Enter the desired length (in feet or in metres) in the 'Quantity' box.
Tutti gli importi indicati in EUR
Nota: • For IEC Class 1 Tolerance (Special Limits of Error), add suffix "-SLE" to Part Number; add 20% to price.
• For High Purity MgO, add suffix "-HP" to Part Number;

Combinare codice prodotto

Costruisci il Tuo Codice Prodotto Qui Sotto
Descrizione delle opzioni:


(1) Cable Type Seleziona da:
K per type K
N per type N

(2) Sheath Diameter Seleziona da:
010 per 010 in.
020 per 020 in.
032 per 032 in.
040 per 040 in.
062 per 062 in.
125 per 125 in.
188 per 188 in.
250 per 250 in.
313 per 313 in.
0.25MM per 0.25 mm
0.5MM per 0.5 mm
0.75MM per 0.75 mm
1.0MM per 1.0 mm
1.5MM per 1.5 mm
2.0MM per 2.0 mm
3.0MM per 3.0 mm
4.5MM per 4.5 mm
6.0MM per 6.0 mm
8.0MM per 8.0 mm
Nota: Non tutte le combinazioni possono essere valide, controlla il foglio delle specifiche per codici prodotti corretti.