FL45100
In-line Flowmeters With Half Union Adaptors
Vedi tutti i modelli qui sotto
-
Direct Reading, Dual Scale: litres/min and USgallons/min
-
Available in In-Line and Panel Mount Styles
-
Models with Protective Shield and for Harsh Environments
-
One-Piece Meter Body of Injection Moulded Polysulfone
-
Floats made of 316SS, TFE , or Hastelloy C
Flussimetri ad area variabile - Visualizza i prodotti correlati
Descrizione
Discontinued, replaced by FL500-Series
FL45100 Series flowmeters feature a rugged, one-piece meter body of
heat- and chemical-resistant injection-moulded polysulfone. A
precision-textured light-admitting surface at the rear of the meter body
diffuses ambient light and creates a softly illuminated background to
enhance readability. These meters are not recommended for applications
involving direct sunlight. Additional features include a stainless steel float
guide and float, 1" FNPT polysulfone adaptors, and FKM O-ring seals. For
harsh applications, units may be ordered with Hastelloy C float guide
and float of either Hastelloy or TFE (depending on flow range).
Models
are also available with 90° adaptors and 1" MNPT connections for panel mount installations.
Specifications
Accuracy: ±3%
Meter Body: Moulded polysulfone
O-Ring Material: FKM
Float: 316 SS, Hastelloy C or TFE - see order table
Temperature Limit: 100°C at 0 psi
Pressure Limit: 10 bar (150 psi) at 21°C
Max Pressure Drop: 1.0 psi
Adaptor Size: 1" FNPT
Dimensions: 368 H x 84 mm W;
with 90° adaptors: 432 H x 381 mm W
Weight: 1.4 kg