Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Three-Wire Ultrasonic Level Transmitter

LVU-303,LVU-301

LVU303_301 Series Ultrasonic Level Transmitter | LVU-303,LVU-301

LVU303_301 Series Ultrasonic Level Transmitter

Vedi tutti i modelli qui sotto

  • 8° Beam Allows Application in Restricted Environments
  • All Plastic Construction
  • LED Digital Display Indicates Level in Inches or Centimeters
  • Push Button Calibration For All User Set Points
  • Built-in 10A Relay May Be Configured For Alarm or Automatic Fill/Empty Operations
  • Fail-Safe Relay Logic Provides Echo and Power Loss Safety
  • Sanitary Model Available
Misure di livello - Visualizza i prodotti correlati

Descrizione

More information about how a Level sensor works in this link.

The three-wire ultrasonic level transmitter is the compact solution for non-contact continuous level measurement in process vessels, storage tanks and open channels. The transmitter also features a built-in 10A relay which can be configured as an alarm on a single set point or latched on two different set points for automatic fill or empty operations. Industrial and municipal liquid examples include sodium hydroxide, wastewater, resin, wax, liquor and bleach. An ultrasonic sound wave is pulsed eight times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor based electronics measure the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below.
The surface of the level being measured must be free of fumes, vapors, foam and the surface must be flat; the signal may be lost if any of these conditions are present.

SPECIFICATIONS
Range: 0.5 to 24.5 feet
Accuracy: ± 0.25% of span
Resolution: 0.125” (3 mm)
Frequency: 50 kHz
Pulse rate: 8 pulses/second
Blocking distance: 6" minimum
Display type: 4 segment LED
Display units: Inch / cm
Supply voltage: 14-36 Vdc
Consumption: 200 mA
Current flow: Source / sink
Signal output: 4-20 mA, 12-36 Vdc
Signal averaging: Fast / slow
Calibration: Push button
Relay current: 10 amp
Relay output: 250 VAC, 10A, 1/2 hp, SPDT
Relay indication: ON / OFF status
Contact resistance: 30 milli½
Fail-safe diagnostic: Relay reverts to safe position
Temperature rating: -40 to 60°C, (-40 to 140°F)
Temp. compensation: Automatic over entire range
Pressure rating: 30 psi @ 25 °C., derated @1.667 psi per °C. above 25 °C.
Enclosure rating: NEMA 4X / IP65
Enclosure material: Polypropylene
Transducer material: PVDF
Mounting threads: 2" NPT (4" female with “-S” option)

Please download PDF file below for full product specifications
Ordinare(Specificare il codice prodotto)

Quello che altre persone hanno comprato: Quando vedi questa icona, fai clic su di essa per espandere un elenco di prodotti che altre persone hanno comprato quando hanno acquistato questo modello.

Codice prodotto/Desc.
Q.tá
Descrizione
Transmitters
  
LVU-301
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Ultrasonic Three-Wire Transmitter,Sinking (4-20 mA)
  
LVU-303
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Ultrasonic Three-Wire Transmitter, Sourcing (4-20 mA)
Accessories
Clicca per espandere/minimizzare una lista di quello che altri hanno comprato con TX4-100
TX4-100
€49.97
Stock: 1 settimana
 
4-Core 7/0.2 mm screened cable white, red, green & black with drain wire, 30 metres
Tutti gli importi indicati in EUR
Nota: For Hygienic Option add “-S” to model number and contact sales for additional price.

CE approval complies with EN50082-2 immunity, EN55011 emission and EN 61010-1 safety standards.

The sourcing transmitter provides internal 4-20 mA excitation and should be used with a sinking device. The transmitter with sinking output requires external excitation or should be used with a sourcing device, such as the LVCN-51-CE continuous relay controller.