Cookies del sito web Omega Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
The LVU30 Series of RoHS
Compliant low-cost ultrasonic
sensors that produce detection
ranges from as close as 100 mm
(4") to greater than 4.5 m (15').
Incorporating state-of-the-art
ultrasonic technology, the sensors
provide precision non-contact
distance measurement for factory
automation or industrial process
control. The LVU30 series of
sensors stand out over all other
systems because of their
affordability, extraordinary ease of
operation, genuinely user-friendly
software, versatility in usercontrolled
outputs, and the ability
to be set up without using a target.
They transmit narrow beam sound
pulses at a user-selected rate
(software triggered), the process
returns echoes, and various outputs
depending on the position of the
target and programming parameters.
SPECIFICATIONS
(Typical at 24 Vdc, 22°C, 24 Vdc and 50% RH)
Ultrasonic Frequency: LVU31: 210 kHz
LVU32: 150 kHz
LVU33: 95 kHz nominal
System Beam Angle: 8 degrees conical
Range: LVU31: 100 mm to 1.3 m, (4 to 50")
LVU32: 180 mm to 2.5 m (7" to 8')
LVU33: 0.3 to 4.5 m (1 to 15') application dependant
Resolution: 0.25 mm (0.01")
Echo Detection Sensitivity: User selectable
Power Required: 12 to 24 Vdc(reverse polarity protected), 30 mA, typical
Output Impedance: 100 Ω for both modes of operation
Proportional Mode Zero and Span Voltages: Programmable from 0 to 10.25 Vdc (factory default: 0 to 10.0 Vdc)
Loss of Echo Voltage: Programmable from 0 to 10.25 Vdc (factory default: 10.25 Vdc)
Response Time: 60 mS
Resolution: 10 bits
Switch Mode Set Point Voltages: 0 or 10.25 Vdc
Set point Hysteresis (Programmable): 0 to 75%
Response Time: < 1 ms
Sampling Rate (Programmable): 0.1 to 100 Hz in 0.1 Hz increments (factory default: 10 Hz)
Target Distance Averaging Rolling Average: From 1 to 32 samples
Boxcar Average: From 1 to 1,024 samples (factory default: 1 sample)
Loss-of-Echo Time-Out: From 1 to 254 consecutive samples missed before time-out (factory default: 1 sample)
Housing Material: PVC
Connection: 1 NPT
Transducer Surface: Custom PPA
Cable: 5 conductor, PVC jacket, 22 AWG, 200 mm (8") pigtail [user-extendable for RS-485 communication to 1,500 m (5,000')]
Operating Temperature: -20 to 65°C (-4 to 149°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Relative Humidity: 0 to 95%, non-condensing
Enclosure Rating: NEMA 6 (IP67)
Programming Requirements Communications Converter: RS-232 (or USB)/RS-485 with automatic send data control
Operating System: Windows® 95/98/NT/2000/XP
† Tutti gli importi indicati in EUR Nota: Comes complete with operator's manual.
We noticed you are from the US. Visit your local site for regional offers and live support.