Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Two-Wire Ultrasonic Level Transmitter

LVU-201A

LVU150 Series Ultrasonic Level Transmitter | LVU-201A

LVU150 Series Ultrasonic Level Transmitter

Vedi tutti i modelli qui sotto

1 anno di garanzia CE
  • Non-Contact Level Transmitter with 4 to 20 mA Output
  • Accurate and Reliable Level Measurement from 0.2 to 5.5 m (0.5 to 18')
  • Automatic Temperature Compensation
  • 8° Beam Allows Application in Restricted Environments
  • All-Plastic Construction
  • Pushbutton Calibration with Display
  • Microprocessor Logic Filtration Eliminates False Echo Signal Returns
  • Failsafe Intelligence Provides Echo Signal Loss Safety
Misure di livello - Visualizza i prodotti correlati

Descrizione

More information about how a Level sensor works in this link.

The LVU-201A 2-wire ultrasonic level transmitter is the compact solution for non-contact continuous level measurement in process vessels, storage tanks, and open channels. This loop-powered device provides accurate level measurement up to 5.5 m (18') and is the ideal choice for more challenging coating or scaling liquids, including sodium hydroxide, waste water, resin, wax and bleach.

An ultrasonic sound wave is pulsed 2 times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor-based electronics measure the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below.

SPECIFICATIONS
Range: 0.2 to 5.5 m (0.5 to 18')
Accuracy: ±0.25% of span
Resolution: 3 mm (0.125")
Frequency: 50 kHz
Pulse Rate: 2 pulses/second
Beam Width: 8° conical
Blocking Distance: 15.2 m (6") minimum
Display Type: 4-segment LCD
Display Units: In/cm
Supply Voltage: 12 to 32 Vdc
Max Loop Resistance: 600 Ω @ 24 Vdc
Signal Output: 4 to 20 mA
Signal Invert: 4 to 20 mA/20 to 4 mA
Calibration: Pushbutton
Mountable Gasket: FKM
Conduit Entrance: Single, 1.2 NPT
CE Compliance: EN61326 EMC
Failsafe Diagnostic: Reverts to 4 mA or 22 mA
Temperature Rating: -20 to 60°C (-4 to 140°F)
Temperature Compensation: Automatic over entire range
Pressure Rating: 30 psi @ 25°C, derated @1.667 psi per °C above 25°C
Enclosure Rating: NEMA 4X (IP66)
Enclosure Material: Polypropylene
Transducer Material: Polyvinylidene fluoride
Mounting threads: 2 NPT
Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
LVU-201A
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Ultrasonic 2-wire transmitter, loop powered (4 to 20 mA)
Accessories
Tutti gli importi indicati in EUR
Nota: Comes complete with operator’s manual.


We noticed you are from the US. Visit your local site for regional offers and live support.