Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Mass Flow Device

FMA-7100, FMA-7200 and FMA-7300

Mass Flow Device | FMA-7100, FMA-7200 and  FMA-7300

Mass Flow Device

Vedi tutti i modelli qui sotto

  • ±1% Full Scale Accuracy
  • ±0.25% of Rate Repeatability
  • Broad Range in a Single Unit to Fit Most Applications
  • Field Selectable Soft Start Eliminates Spoiled Batches
  • Normally Closed Valve
  • Low Pressure Drop
  • Compact Design
  • For Clean, Non-Coating Gases
Misuratori di portata massici elettronici - Visualizza i prodotti correlati

Descrizione

Find how a Flow meter works on this link.

OMEGA™ FMA-7000E Mass Flow Controllers accurately measure gases on the basis of mass flow. The flow sensor produces an electrical output signal linear with the flowrate used for indicating, recording, and/or control purposes. It eliminates the need for continuous monitoring and readjustment of gas pressures to provide a stable gas flow. This is accomplished automatically by an electromagnetically actuated flowrate control valve.

OPERATING PRINCIPLE The operating principle of the controller is thermodynamic. A precision power supply directs heat to the midpoint of the sensor tube carrying the flow. On the same tube, equidistant upstream and downstream of the heat input, are resistance temperature measuring elements. With no flow, the heat reaching each temperature element is equal. With increasing flow, the flow stream carries heat away from the upstream element, and carries it towards the downstream element. An increasing temperature difference develops between the two elements and this difference is proportional to the mass flowrate of the gas. A bridge circuit interprets the temperature difference and an amplifier provides the output to the control circuitry as well as a 0-5 Vdc output signal.

SPECIFICATIONS
Accuracy: ±1% FS including linearity at calibration conditions, ±1.5% FS including linearity for flow ranges greater than 20 SLM
Repeatability: ±0.25% of rate
Response Time: <3 second response to within 2% FS final value with a 0 to 100% command step
Set Point Input: 0 to 5 Vdc or 1000Ω potentiometer
Output: 0 to 5 Vdc into 2000Ω minimum load; 3 mV rms max. ripple
Maximum Pressure: 1500 psig (Note: Additional charge for pressures >999 PSI). Pressure drop 5 to 50 psid
Temperature Range: 4 to 66°C(40 to 150°F) ambient and gas
Temp. Sensitivity:
    Zero: < ±0.075% FS per °C
    Span: <±1.0% FS shift over 10 to 50°C (50 to 122°F) range
Power Supply Sensitivity: ±0.09% FS per % power supply voltage variation Mounting Attitude Sensitivity: ±0.5% maximum FS deviation after zeroing
Leak Integrity: 1 x 10-9 Atm. scc/sec helium
Control Range: 50 to 1
Pressure Sensitivity: ±0.03% per psi up to 200 psig (N2)
Power: +15 Vdc at 35 mA DC, -15 Vdc at 180 mA dc, 3.5 watts power consumption
Wetted Parts: 316 and 430SS, FKM
Connections: ¼" stainless steel compression fittings
Electrical Connections: Card edge, 20 terminals, gold over low stress nickel-plated copper
Accessories Included: Mating connector with 1.5 m (5') ribbon cable model. Easy connector/cable assemblies available


Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.

Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
FMA-7102E-(*)
Consultare l'Ufficio Commerciale  
Stock: 
 
 
mass flow meter, 0 to 50 SCCM max range. Specify inlet/outlet pressure in order comments. NB: Additional charge of £375 for >999 psi

Ordina per Codice Prodotto

Codice prodotto
Q.tá
Codice prodotto
Q.tá


Tutti gli importi indicati in EUR
Nota: Comes complete with connector and operator's manual.

Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.

Calibrations done at ambient (20C/70F) temperature only.