Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

 - Discontinued Pressure Volume Controllers, AVC-1000 and AVC-3000, Vacuum to 1000 or Vacuum to 3000

AVC-1000 and AVC-3000

 | AVC-1000 and AVC-3000

Vedi tutti i modelli qui sotto

  • Accurately Adjusts Vacuum or Pressure In Closed Systems
  • 1000 or 3000 PSI Models
  • Built In Balance Valve Prevents Excessive Differential Pressures
Valvole , regolatori e convertitori I / P - Visualizza i prodotti correlati

Descrizione

OMEGA™ Pressure Volume Controllers provide an easy-to-use means of rapidly and accurately adjusting the pressure in a closed system. These pressure controllers provide the ability to precisely adjust pressure within 0.00025 psi. When used with digital pressure gauges, dial gauges, transducers, pressure switches, air deadweight testers, manometers and other similar devices, they provide a fast and accurate means of setting a precise pressure. OMEGA Pneumatic Controllers are available for use with pressures up to 3000 psi. Engineered to provide superior performance and safety, these devices incorporate a unique pressure balance valve.This valve is opened during initial system pressurization. When opened, the valve provides equal pressure to both sides of the piston assembly. After the system has been pressurized, the valve is closed. When the valve is closed, a change in piston position will result in a change in the pressure within the system. Simply turning the large pressure adjust knob repositions the piston to increase or decrease the pressure. Equalization of pressure on both sides of the piston assures ease of pressure setting. In addition, the valve performs a safety function. The balance valve will open automatically if an excessive pressure differential is generated across the piston. In essence, the valve serves as a safety relief valve and protects the controller from damage due to excessive pressure differentials within the unit.
SPECIFICATIONS AVC-1000 AVC-3000
Range (psi) Vacuum to 1000 Vacuum to 3000
Proof (psi) 2000 6000
Burst (psi) 6000 min 12,000 min
Resolution (psi) 0.00025 0.0005
Volume Change (Cubic Inches) 57.35 mL (3.5 cubic in) 40.97 (2.5 cubic in)
Mechanical Rotation (Total Turns) 31 61
Connection (Female) 1/8 NPT 1/8 NPT
Operating Temp Range -18 to 49°C (20 to 120°F)
Construction Aluminum body, stainless steel, brass, PTFE, DelrinR and Buna-N
Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
AVC-1000
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Pressure Volume Controller 1000 psi operating range
AVC-3000
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Pressure Volume Controller 3000 psi operating range
Tutti gli importi indicati in EUR
We noticed you are from the US. Visit your local site for regional offers and live support.