Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

PX02-5V Series -

NOT CE Compliant-Not for sale in UK/EU

PX02-5V

 | PX02-5V

989,34 PX02K1-100G5T

  • As an alternative see the PX409 Series
  • Internal Shunt Resistor for Easy System Checks
  • FM Intrinsically Safe
  • All Stainless Steel Construction
  • 5 Point NIST Traceable Calibration
  • Hermetically Sealed Double Diaphragm Design for Harsh Environments
  • Available in Gage, Absolute, Sealed Gage Models
  • Cable or Connector Models
  • Optional Pressure Ports to Fit Most Industrial Applications
Trasduttori di pressione - Visualizza i prodotti correlati

Descrizione

OMEGA’s PX02 Series is a high accuracy, amplified voltage output, industrial pressure transducer. All stainless steel construction and a hermetically sealed case makes the PX02 suitable for harsh industrial environments. It is a true high accuracy industrial device with FM Intrinsically Safe rating standard. A broad temperature compensated range of 16 to 71°C (60-160°F) and excellent temperature compensation make this transducer very stable with fluctuating temperatures. The PX02 is available in gage, absolute or sealed models as well as PSI or metric ranges. NPT and 7 /16-20 O-ring seal fittings are available for industrial and Hydraulic applications.

SPECIFICATIONS:

mV/V OUTPUT

Excitation: 24 - 32 Vdc

Output: 0 -5 Vdc ± 10%adj;

Linearity: ±0.15% FS

Hysteresis: ±0.1% FS

Repeatability: ±0.05% FS

Zero Balance: 0 Vdc±10%adj.

Agency Approvals: Standard:

FM Intrinsically Safe IS/I.II.III/1/CDEFG

Shunt Calibration:

Value specified on Calibration sheet

Sensing Element:

4 active-arm bridge, using thick film

strain gages in a hermetically sealed

chamber

Operating Temp Range:

-46 to 121°C (-50 to 250°F)

Compensated Temp Range:

16 to 71°C (60 to 160°F)

Thermal Effects:

Span: 0.003% Rdg/°F

Zero: 0.0025% FS/F

Proof Pressure: 150% of rated pressure

Burst Pressure: 300% of rated pressure

Wetted Parts: 17-4PH SS

Pressure Port: Ranges < 10,000 psi

Style “K” 7/16 -20 UNF female

Style “C” 1/4 NPT male

Ranges ³ 10,000 psi

Style “S” 9/16 -18, 1/4 inch HP tube.

Also available:

1/4 -18 NPT female or

7/16 -20 UNF male

Electrical Connection:

Style "1" = PT1H-10-6P or Equal

Style "0" = 10ft (3m) Cable

Mating Connector:

PT06F-10-6S (not included)


Compatible meters: DP41-E*, DP25-E*, DP24-E*
*(PSS-D15B power supply required)

For special options consult Sales or Pressure Engineering.

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
Tutti gli importi indicati in EUR
Nota: (1) 2 and 5 psi Ranges available only on amplified output. (2) 1/4 HP Tube Fitting supplied for ranges 10,000 psi and above. (3)All Gage Pressure Ranges also available in Sealed Gage Pressure.

Combinare codice prodotto

Costruisci il Tuo Codice Prodotto Qui Sotto
Descrizione delle opzioni:


(1) Pressure Port Seleziona da:
C per 1/4 -18 NPT-M
D per 1/4 -18 NPT-F
J per 7/16 -20 UNF-M
K per 7/16 -20 UNF-F
S per 1/4 HP Tube Fitting (for models 10000 psi and over)

(2) Electrical Connection Seleziona da:
0 per 10ft cable (std)
1 per PT1H-10-6P Connector
5 per Lightening protected Amplifier Box (no charge) (4-20 mA models only)

(3) Range (psi) Seleziona da:
002 per 0-2
005 per 0-5
010 per 0-10
015 per 0-15
020 per 0-20
025 per 0-25
050 per 0-50
075 per 0-75
100 per 0-100
150 per 0-150
200 per 0-200
250 per 0-250
300 per 0-300
500 per 0-500
750 per 0-750
1K per 0-1000
1.5K per 0-1500
2K per 0-2000
3K per 0-3000
3.5K per 0-3500
5K per 0-5000
7.5K per 0-7500
10K per 0-10000
20K per 0-20000
30K per 0-30000

(4) Units Seleziona da:
G per Gage Model
A per Absolute Model
S per Sealed Gage Model

(5) Output Seleziona da:
V per mV/V Output
5T per 0 to 5Vdc Output
5Z per Isolated 0 to 5 Vdc
10T per 0 to 10 Vdc Output
I per 4 to 20mA Output

(6) Options (Leave blank for no options) Seleziona da:
per no options leave blank
-OL per Overload Stops +$65
-OX per Cleaned for Oxygen use (takes 2 weeks +$75)