Cookies del sito web Omega
Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Intrinsically Safe, Flanged Mounted Pulse Radar Level Transmitter

LR21

Intrinsically Safe, Flanged Mounted Pulse Radar Level Transmitter | LR21

2.956,00 LR21-5321-30-00

1 anno di garanzia CE
  • 316L antenna with PTFE inner shield for corrosive media
  • Configuration via push button display or HART communicator
  • 26 GHz. pulse radar is unaffected by vapor or condensation
  • 12” (30cm) dead band enables utilization of the entire tank
  • LCD displays level in feet or meters with percent of span bar
  • Optional display mode indicates the echo signal return curve
  • Fail-safe diagnostics with selectable signal fail-safe outputs
  • Recognition, storage and rejection of false echo signal returns
  • IP67 stainless enclosure with polycarbonate display window
Misure di livello - Visualizza i prodotti correlati

Descrizione

The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or HART communicator. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.

PTFE Shield
Sufuric and nitric acids are strong mineral acids that are widely used in industrial and commercial applications. Highly vaporous and corrosive, they’re difficult to measure and harsh on equipment. The non-contact LR21 is an excellent choice for this media, as its 26 GHz. pulse radar measurement is unaffected by extreme vapor, and the antenna’s PTFE inner shield, provides reliable corrosion resistance.

SPECIFICATIONS

Connection Type: 3" Flange (ANSI)
Display Type: LCD
Measurment Unit: Ft/M
Measurement Type: Level
Supply Voltage: 21.6 to 26.4 Vdc
Retransmission/Analog Output: 4 to 20 mA, HART 7
Maximum Operating Pressure: 72 psi
Maximum Liquid Temperature: 150C (302F)
Minimum Liquid Temperature: -40C (-40F)
Accuracy Value: +/- 3mm
Minimum Ambient Temperature: -40°C (-40°F)
Wetted Materials: 316L SS, PTFE
Beam Angle: 12°
Frequency: 26 GHz
Certification: FCC
Classification: Intrinsically safe
Ordinare(Specificare il codice prodotto)
Codice prodotto/Desc.
Q.tá
Descrizione
LR21-5321-30-00
2.956,00
Stock: 1 settimana
 
Intrinsically Safe, Flanged Mounted Pulse Radar Level Transmitter
Accessories
LB12-1001
1,066.00
Stock: 1 settimana
 
Intrinsic Safety Barrier
Tutti gli importi indicati in EUR
We noticed you are from the US. Visit your local site for regional offers and live support.