Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

0.315" (0.8 cm) and 0.475" (1.2 cm) Diameter Round Cross-section Single-End Terminal Tubular Heaters

STRI and STRS

0.315

Vedi tutti i modelli qui sotto

  • Style STRI
    • INCOLOY Sheath
    • 225 - 2,400 Watts
    • 120 and 240 Volt
    • 4 - 30 W/In2
    • 1600°F (870° C) Maximum Sheath Temperature
  • Style STRS
    • Steel Sheath
    • 150 - 2,725 Watts
    • 120 and 240 Volt
    • 3 - 20 W/In2
    • 750°F (450°C) Maximum Sheath Temperature
Riscaldatori tubolari - Visualizza i prodotti correlati

Descrizione

Click here if you want to know more about electric heaters.

Syle STRI
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with flange, screwplug, threaded fitting or other means of mounting.

ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in many cases. Use slim elements to concentrate heat into a confined area, taking up less space than a U-shaped element with terminals at each end.

.315" (8 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) INCOLOY Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
2251203011 7/8 (30)7 1/8 (18)STRI-1248/120V0.4
3251203015 7/8 (40)11 1/8 (28)STRI-1648/120V0.4
3252403015 7/8 (40)11 1/8 (28)STRI-1648/240V0.4
4501203019 7/8 (50)15 1/8 (38)STRI-2048/120V0.4
4502403019 7/8 (50)15 1/8 (38)STRI-2048/240V0.4
5751203023 7/8 (60)19 1/8 (49)STRI-2448/120V0.4
5752403023 7/8 (60)19 1/8 (49)STRI-2448/240V0.4
7001203027 7/8 (70)23 1/8 (59)STRI-2848/120V0.8
7002403027 7/8 (70)23 1/8 (59)STRI-2848/240V0.8
8001203031 7/8 (80)27 1/8 (69)STRI-3248/120V0.8
8002403031 7/8 (80)27 1/8 (69)STRI-3248/240V0.8
9251203035 7/8 (91)31 1/8 (79)STRI-3648/120V0.8
9252403035 7/8 (91)31 1/8 (79)STRI-3648/240V0.8
1,0501203039 7/8 (101)35 1/8 (89)STRI-4048/120V1
1,0502403039 7/8 (101)35 1/8 (89)STRI-4048/240V1
1,1751203043 7/8 (111)39 1/8 (99)STRI-4448/120V1
1,1752403043 7/8 (111)39 1/8 (99)STRI-4448/240V1
1,2001202847 7/8 (122)43 1/8 (110)STRI-4848/120V1
1,2752403047 7/8 (122)43 1/8 (110)STRI-4848/240V1
1,2001202651 7/8 (132)47 1/8 (120)STRI-5248/120V1.3
1,4002403051 7/8 (132)47 1/8 (120)STRI-5248/240V1.3
1,1501202355 7/8 (142)51 1/8 (130)STRI-5648/120V1.3
1,5252403055 7/8 (142)51 1/8 (130)STRI-5648/240V1.3
1,07512013.759 7/8 (152)55 1/8 (140)STRI-6048/120V1.3
1,6502403059 7/8 (152)55 1/8 (140)STRI-6048/240V1.3
8751201371 7/8 (183)67 1/8 (171)STRI-7248/120V1.3
2,0002403071 7/8 (183)67 1/8 (171)STRI-7248/240V1.3
7501201083 7/8 (213)79 1/8 (201)STRI-8448/120V1.8
2,3502403083 7/8 (213)79 1/8 (201)STRI-8448/240V1.8
650120795 7/8 (243)91 1/8 (231)STRI-9648/120V1.8
2,4002402795 7/8 (243)91 1/8 (231)STRI-9648/240V1.8
5751206107 7/8 (274)103 1/8 (262)STRI-10848/120V2.5
2,30024023107 7/8 (274)103 1/8 (262)STRI-10848/240V2.5
5001204119 7/8 (304)115 1/8 (292)STRI-12048/120V2.5
2,00024018119 7/8 (304)115 1/8 (292)STRI-12048/240V2.5


.475 Diameter (1.2cm) Round Cross-Section Single-Ended Terminals


Watts Volts W/In2 Dimensions in (cm) INCOLOY Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
3251203011 7/8 (30)7 3/16 (18)STRI-1245/1200.5
5001203015 7/8 (40)11 3/16 (28)STRI-1645/1200.5
5002403015 7/8 (40)11 3/16 (28)STRI-1645/2400.5
6751203019 7/8 (50)15 3/16 (39)STRI-2045/1200.5
6752403019 7/8 (50)15 3/16 (39)STRI-2045/2400.5
8501203023 7/8 (60)19 3/16 (49)STRI-2445/1200.5
8502403023 7/8 (60)19 3/16 (49)STRI-2445/2400.5
10251203027 7/8 (70)23 3/16 (59)STRI-2845/1201
10252403027 7/8 (70)23 3/16 (59)STRI-2845/2401
12251203031 7/8 (80)27 3/16 (69)STRI-3245/1201
12252403031 7/8 (80)27 3/16 (69)STRI-3245/2401
14001203035 7/8 (91)31 3/16 (79)STRI-3645/1201
14002403035 7/8 (91)31 3/16 (79)STRI-3645/2401
15751203039 7/8 (101)35 3/16 (89)STRI-4045/1201.3
15752403039 7/8 (101)35 3/16 (89)STRI-4045/2401.3
17501203043 7/8 (111)39 3/16 (100)STRI-4445/1201.3
17502403043 7/8 (111)39 3/16 (100)STRI-4445/2401.3
15751202547 7/8 (122)43 3/16 (110)STRI-4845/1201.3
19252403047 7/8 (122)43 3/16 (110)STRI-4845/2401.3
14501202151 7/8 (132)47 3/16 (120)STRI-5245/1201.8
21002403051 7/8 (132)47 3/16 (120)STRI-5245/2401.8
13251201755 7/8 (142)51 3/16 (130)STRI-5645/1201.8
22752403055 7/8 (142)51 3/16 (130)STRI-5645/2401.8
12251201559 7/8 (152)55 3/16 (140)STRI-6045/1201.8
24752403059 7/8 (152)55 3/16 (140)STRI-6045/2401.8
10001201071 7/8 (183)67 3/16 (171)STRI-7245/1201.8
30002403071 7/8 (183)67 3/16 (171)STRI-7245/2401.8
850120783 7/8 (231)79 3/16 (201)STRI-8445/1202.3
34002402983 7/8 (213)79 3/16 (201)STRI-8445/2402.3
750120695 7/8 (243)91 3/16 (231)STRI-9645/1203.3
30002402295 7/8 (243)91 3/16 (231)STRI-9645/2403.3
6501204107 7/8 (274)103 3/16 (261)STRI-10845/1203.3
260024017107 7/8 (274)103 3/16 (261)STRI-10845/2403.3
5751203119 7/8 (304)115 3/16 (292)STRI-12045/1203.3
230024013119 7/8 (304)115 3/16 (292)STRI-12045/2403.3


Syle STRS
APPLICATIONS
Molds and other heat-transferring metal parts and air heating applications. Immersion heating with flange, screwplug, threaded fitting or other means of mounting.

ADVANTAGES
Elements with both terminals at one end, in dies, can simplify wiring in many cases. Use slim elements to concentrate heat into a confined area, taking up less space than a U-shaped element with terminals at each end.

.315" (8 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) Steel Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
1501202011 7/8 (30)71/8 (18)STRS-1248/120V0.4
2251202015 7/8 (40)11 1/8 (28)STRS-1648/120V0.4
2252402015 7/8 (40)11 1/8 (28)STRS-1648/240V0.4
3001202019 7/8 (50)15 1/8 (38)STRS-2048/120V0.4
3002402019 7/8 (50)15 1/8 (38)STRS-2048/240V0.4
3751202023 7/8 (60)19 1/8 (49)STRS-2448/120V0.4
3752402023 7/8 (60)19 1/8 (49)STRS-2448/240V0.4
4501202027 7/8 (70)23 1/8 (59)STRS-2848/120V0.8
4502402027 7/8 (70)23 1/8 (59)STRS-2848/240V0.8
5501202031 7/8 (80)27 1/8 (69)STRS-3248/120V0.8
5502402031 7/8 (80)27 1/8 (69)STRS-3248/240V0.8
6251202035 7/8 (91)31 1/8 (79)STRS-3648/120V0.8
6252402035 7/8 (91)31 1/8 (79)STRS-3648/240V0.8
7001202039 7/8 (101)35 1/8 (89)STRS-4048/120V1
7002402039 7/8 (101)35 1/8 (89)STRS-4048/240V1
7751202043 7/8 (111)39 1/8 (99)STRS-4448/120V1
7752402043 7/8 (111)39 1/8 (99)STRS-4448/240V1
8501202047 7/8 (122)43 1/8 (110)STRS-4848/120V1
8502402047 7/8 (122)43 1/8 (110)STRS-4848/240V1
9251202051 7/8 (132)47 1/8 (120)STRS-5248/120V1.3
9252402051 7/8 (132)47 1/8 (120)STRS-5248/240V1.3
10251202055 7/8 (142)51 1/8 (130)STRS-5648/120V1.3
10252402055 7/8 (142)51 1/8 (130)STRS-5648/240V1.3
107512019.759 7/8 (152)55 1/8 (140)STRS-6048/120V1.3
11002402059 7/8 (152)55 1/8 (140)STRS-6048/240V1.3
8751201371 7/8 (183)67 1/8 (171)STRS-7248/120V1.3
13252402071 7/8 (183)67 1/8 (171)STRS-7248/240V1.3
7501201083 7/8 (213)79 1/8 (201)STRS-8448/120V1.8
15752402083 7/8 (213)79 1/8 (201)STRS-8448/240V1.8
650120795 7/8 (243)91 1/8 (231)STRS-9648/120V1.8
18002402095 7/8 (243)91 1/8 (231)STRS-9648/240V1.8
5751206107 7/8 (274)103 1/8 (262)STRS-10848/120V2.5
205024020107 7/8 (274)103 1/8 (262)STRS-10848/240V2.5
5001204119 7/8 (304)115 1/8 (292)STRS-12048/120V2.5
200024013119 7/8 (304)115 1/8 (292)STRS-12048/240V2.5

.475" (12 mm) Diameter Round Cross-Section Single-End Terminal



Watts Volts W/In2 Dimensions in (cm) Steel Sheath
Model No.
Weight
(Lb.)
Sheath A Heated B
2001202011 7/8 (30)7 3/16 (18)STRS-1245/120V0.5
3251202015 7/8 (40)11 3/16 (28)STRS-1645/120V0.5
3252402015 7/8 (40)11 3/16 (28)STRS-1645/240V0.5
4501202019 7/8 (50)15 3/16 (38)STRS-2045/120V0.5
4502402019 7/8 (50)15 3/16 (38)STRS-2045/240V0.5
5751202023 7/8 (60)19 3/16 (49)STRS-2445/120V0.5
5752402023 7/8 (60)19 3/16 (49)STRS-2445/240V0.5
7001202027 7/8 (70)23 3/16 (59)STRS-2845/120V1
7002402027 7/8 (70)23 3/16 (59)STRS-2845/240V1
8001202031 7/8 (80)27 3/16 (69)STRS-3245/120V1
8002402031 7/8 (80)27 3/16 (69)STRS-3245/240V1
9251202035 7/8 (91)31 3/16 (79)STRS-3645/120V1
9252402035 7/8 (91)31 3/16 (79)STRS-3645/240V1
10501202039 7/8 (101)35 3/16 (89)STRS-4045/120V1.3
10502402039 7/8 (101)35 3/16 (89)STRS-4045/240V1.3
11751202043 7/8 (111)39 3/16 (99)STRS-4445/120V1.3
11752402043 7/8 (111)39 3/16 (99)STRS-4445/240V1.3
12751202047 7/8 (122)43 3/16 (110)STRS-4845/120V1.3
12752402047 7/8 (122)43 3/16 (110)STRS-4845/240V1.3
14001202051 7/8 (132)47 3/16 (120)STRS-5245/120V1.8
14002402051 7/8 (132)47 3/16 (120)STRS-5245/240V1.8
13251201755 7/8 (142)51 3/16 (130)STRS-5645/120V1.8
15252402055 7/8 (142)51 3/16 (130)STRS-5645/240V1.8
12251201559 7/8 (152)55 3/16 (140)STRS-6045/120V1.8
16502402059 7/8 (152)55 3/16 (140)STRS-6045/240V1.8
10001201071 7/8 (183)67 3/16 (171)STRS-7245/120V1.8
20002402071 7/8 (183)67 3/16 (171)STRS-7245/240V1.8
850120783 7/8 (231)79 3/16 (201)STRS-8445/120V2.3
23502402083 7/8 (213)79 3/16 (201)STRS-8445/240V2.3
750120695 7/8 (243)91 3/16 (231)STRS-9645/120V3.3
27252402095 7/8 (243)91 3/16 (231)STRS-9645/240V3.3
6501204107 7/8 (274)103 3/16 (262)STRS-10845/120V3.3
260024017107 7/8 (274)103 3/16 (262)STRS-10845/240V3.3
5751203119 7/8 (304)115 3/16 (292)STRS-12045/120V3.3
230024013119 7/8 (304)115 3/16 (292)STRS-12045/240V3.3
If element is to be bent, specify "must be annealed".

Tutti gli importi indicati in EUR
Nota: When used as an immersion heater, specify “sealed end”.

Combinare codice prodotto

Costruisci il Tuo Codice Prodotto Qui Sotto
Descrizione delle opzioni:


(1) Style Seleziona da:
STRI per style STRI
STRS per style STRS

(2) Shealth A Seleziona da:
12 per 11 7/8 in.
16 per 15 7/8 in.
20 per 19 7/8 in.
24 per 23 7/8 in.
28 per 27 7/8 in.
32 per 31 7/8 in.
36 per 35 7/8 in.
40 per 39 7/8 in.
44 per 43 7/8 in.
48 per 47 7/8 in.
52 per 51 7/8 in.
56 per 55 7/8 in.
60 per 59 7/8 in.
72 per 71 7/8 in.
84 per 83 7/8 in.
96 per 95 7/8 in.
108 per 107 7/8 in.
120 per 119 7/8 in.

(3) Diamter Round Cross-Section Single-End Terminal Seleziona da:
45 per 0.475 in.
48 per 0.315 in.

(4) Voltage Seleziona da:
120V per 120 V
480V per 480 V
Nota: Non tutte le combinazioni possono essere valide, controlla il foglio delle specifiche per codici prodotti corretti.
We noticed you are from the US. Visit your local site for regional offers and live support.