Cookies del sito web Omega
Utilizziamo i cookies nel nostro sito web. Questi cookies sono necessari per consentire al sito web di funzionare correttamente. Se si continua senza modificare la propria configurazione del browser, si acconsente a ricevere i cookies dal nostro sito web. Per maggiori chiarimenti sull'utilizzo dei cookies, cliccare qui
Vicino
Carrello  |  Contatto  | 
NUMERO DI TELEFONO GRATUITO (solo dall'Italia) 800 906 907
INTERNAZIONALE+39 022 333 1521
Layer N Banner

Counter, Totalizer, Event Transmitter
Part of the NOMAD®Family
These products are not CE marked and use a frequency band which is not approved for use in Europe

OM-CP-RFPULSE101

Counter, Totalizer, Event TransmitterPart of the NOMAD®Family These products are not CE marked and use a frequency band which is not approved for use in Europe | OM-CP-RFPULSE101

Vedi tutti i modelli qui sotto

5 Anni di Garanzia
  • Programmable Engineering Units
  • Automatically Converts your PC
    into a Strip Chart recorder
  • Low Battery Warning
  • Miniature Size
  • Interfaces to Tipping Bucket Rain
    Gauges or Pulse Output Flow Meters
  • Real Time Operation
  • Programmable Scale Factor/Offset
    Value Basic Unit

Descrizione

The OM-CP-RFPULSE101A is a low-cost transmitting device that will sense a pulse input or contact closure from external sources such as transducers or pulse initiators (gas, water, and electric meters) and transforms those inputs into engineering units such as gallons/minute. Once activated, the OM-CP-RFPULSE101A senses and transmits the number of pulses/ contact closures that occur within adjacent "time bin" periods. The bin period is 30 seconds to 12 hours. At the end of each bin period, the total number of pulses/counts is transmitted.

The OM-CP-RFPULSE101A then starts another bin period. It will also transmit the current status of its input. This is ideal for recording the status of a contact closure. Data is received at the PC using our receiving antenna that attaches directly to the serial port. All received data is time and date stamped and stored directly in your PC. Transmitted data is also logged to the device’s memory for added data security. The convenient slide switch allows the transmitter to be turned On or Off without affecting the operation of the device.

The Windows software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can also be exported to a text or Microsoft Excel file.

Specifications
Maximum Pulse Rate:
100 Hz
Minimum Input Active (Low) Time: 4 ms
Minimum Input Inactive (High) Time: 4 ms
Input Signal: TTL, dry contact, inernal pullup, +30 Vdc max
Input Low Signal: < 0.4 Vdc
Input High Signal: < 2.7 Vdc
Input Connection: Screw terminal
Input Impedance: > 1 K .
Readings: 4095 readings with selectable memory wrap
Recording Interval: 30 seconds to 12 hours,
selectable in software
Range: 36 m (120 ft) line if sight
RF Baud Rate: 4800 baud
RF Carrier Frequency: 418 MHz
RF Transmitter Operation:
Configurable in software
RF Transmission Interval: 30 seconds to 12 hours,
selectable in software
Start Time: Start time and data programmable through software,
up to six months in advance
Real Time Recording: Device may be used with
PC to monitor and record data in real time
Engineering Units: Stored in device, user may define
any desired scale and offset from ±1.0000E-31 to ±9.9999E+31
Power: 3.6 V lithium battery (included)
Battery Life: At 15 minute reading rate,
25°C: up to 6 months (100 Hz input,
10% duty cycle); up to 1 year
(25 Hz input, 10% duty cycle);
up to 5 years (1 Hz input, 1% duty cycle)
Time Accuracy: ±1 minute/month (at 20 to 30°C)
Data Format: Date and time stamped pulses,
other engineering units programmable through software
Direct Computer Interface: PC serial or RS232C COM
(interface cable required), 57600 baud
Software: Windows 95/98/NT/2000/XP
Operating Environment: -20 to 80°C (-4 to 176°F)
5 to 95% RH non-condensing
Dimensions: 35 x 54 x 15mm
(1.4 H x 2.15 W x 0.6 D)
Enclosure: ABS plastic
These products are not CE marked and use a frequency band which is not approved for use in Europe
Ordinare(Specificare il codice prodotto)

Quello che altre persone hanno comprato: Quando vedi questa icona, fai clic su di essa per espandere un elenco di prodotti che altre persone hanno comprato quando hanno acquistato questo modello.

Codice prodotto/Desc.
Q.tá
Descrizione
  
OM-CP-RFPULSE101A
Consultare l'Ufficio Commerciale  
Stock: 
 
 
wireless counter/totalizer/event datalogger
Clicca per espandere/minimizzare una lista di quello che altri hanno comprato con OM-CP-RFC101A
OM-CP-RFC101A
Consultare l'Ufficio Commerciale  
Stock: 
 
 
Windows software and 4ft RS-232 cable with DB9F termination and receiving antenna
Clicca per espandere/minimizzare una lista di quello che altri hanno comprato con OM-CP-BAT105
OM-CP-BAT105
24.16
Stock: In magazzino
 
Replacement 3.6 V lithium battery
Tutti gli importi indicati in EUR
Nota: Operator's manual and RS-232 cable are included with the OM-CP-RFC101A Windows software (software sold separately).
These products are not CE marked and use a frequency band which is not approved for use in Europe

Manuali dei prodotti:

Download OM-CP Series - Data Logger and Software User Guide
Download OM-CP Series - Data Logger Quickstart Guide
We noticed you are from the US. Visit your local site for regional offers and live support.